WATER LEAKED ANALYSIS IN THE GAS AIR HEATER IN PT CIREBON POWER SERVICE

Authors

  • Elli Prastyo Akamigas Balongan Indramayu, Indonesia
  • Syamsul Ma'arif Department Chemical Engineering, Akamigas Balongan, Indramayu, Indonesia

DOI:

https://doi.org/10.33603/jgst.v4i3.3997

Abstract

PT. Cirebon Power Services is the first steam power plant (PLTU) in Indonesia that uses Supercritical Boiler technology. Combustion in a boiler using coal fuel produces hot gas which must be disposed of by utilizing a vacuum from the ID Fan and releasing it into the atmosphere. Gas Air Heater is a device that utilizes convection heat transfer from boiler exhaust heat to heat Primary Air and Secondary Air. The analysis was carried out by comparing the Gas Air Heater A and B through three parameters namely Air Leakage, X Ratio, and Efficiency. Data was collected from 31 December 2019 to 30 January 2020. The efficiency value of Gas Air Heater A was obtained 66% - 68% and Gas Air Heater B was 62% - 64%. The value of Air Leakage Gas Air Heater A is obtained 6% - 9% and Gas Air Heater B 10% - 12%. The value of X Ratio of Gas Air Heater A is 0.74 to 0.77, greater than Gas Air Heater B 0.68% to 0.71%.

Author Biography

Elli Prastyo, Akamigas Balongan Indramayu

Department Chemical Engineering, Akamigas Balongan, Indramayu

References

Doosan Heavy Industri. (2010). Description of Boiler and Auxilliaries 1x660MW. Cirebon.

Dukelow, S.G..Agustus 1984. Improving Boiler Efficiency. (terjemahan). Gresik: Perusahaan Umum Listrik Negara Pembangkitan dan Penyaluran Jawa Bagian Timur Sektor Gresik.

Eko Sulistyo, M. Arif Mintorogo. Jurnal Power Plant ISSN no. 2356-1513. Pengaruh Overhaul Terhadap Performa Sistem Pelumasan Air Heater.

Holman, J. P. 2010. Heat Transfer. 10th Edition, McGraw Hill: Boton

Icropera, Frank P. & Witt, D.P.D. 1966. Fundamentals of Heat and Mass Transfer 7th Edition. United States of America: John Wiley & Sons, Inc.

M. Faza Ghani Zaki, Abdul Ghofur. 2020. Jurnal Rotary Vol. 2 No. 1. Analisa Efektivitas Heat Transfer SAH PLTU dengan Metode Asme 4.0 dan 4.3.

Mulyono, Anis Roihatin, Phypit Marisa. 2019. Jurnal Teknik Energi Vol. 15 No. 2. Analisis Pengaruh Pengganti Heating Element Terhadap Kinerja Air Preheater Type Ljungstorm di PLTU Jateng 2 Adipala 1 x 660 MW.

Vendy Antono, Ismail Darmawan. 2016. Jurnal Power Plant Vol. 4 No. 3 Jurnal. Analisis Efisiensi Air Preheater Sebelum Overhaul dan Sesudah Overhaul di UJP PLTU Banten 3 Lontar Unit 3.