WATER LEAKED ANALYSIS IN THE GAS AIR HEATER IN PT CIREBON POWER SERVICE
DOI:
https://doi.org/10.33603/jgst.v4i3.3997Abstract
PT. Cirebon Power Services is the first steam power plant (PLTU) in Indonesia that uses Supercritical Boiler technology. Combustion in a boiler using coal fuel produces hot gas which must be disposed of by utilizing a vacuum from the ID Fan and releasing it into the atmosphere. Gas Air Heater is a device that utilizes convection heat transfer from boiler exhaust heat to heat Primary Air and Secondary Air. The analysis was carried out by comparing the Gas Air Heater A and B through three parameters namely Air Leakage, X Ratio, and Efficiency. Data was collected from 31 December 2019 to 30 January 2020. The efficiency value of Gas Air Heater A was obtained 66% - 68% and Gas Air Heater B was 62% - 64%. The value of Air Leakage Gas Air Heater A is obtained 6% - 9% and Gas Air Heater B 10% - 12%. The value of X Ratio of Gas Air Heater A is 0.74 to 0.77, greater than Gas Air Heater B 0.68% to 0.71%.
References
Doosan Heavy Industri. (2010). Description of Boiler and Auxilliaries 1x660MW. Cirebon.
Dukelow, S.G..Agustus 1984. Improving Boiler Efficiency. (terjemahan). Gresik: Perusahaan Umum Listrik Negara Pembangkitan dan Penyaluran Jawa Bagian Timur Sektor Gresik.
Eko Sulistyo, M. Arif Mintorogo. Jurnal Power Plant ISSN no. 2356-1513. Pengaruh Overhaul Terhadap Performa Sistem Pelumasan Air Heater.
Holman, J. P. 2010. Heat Transfer. 10th Edition, McGraw Hill: Boton
Icropera, Frank P. & Witt, D.P.D. 1966. Fundamentals of Heat and Mass Transfer 7th Edition. United States of America: John Wiley & Sons, Inc.
M. Faza Ghani Zaki, Abdul Ghofur. 2020. Jurnal Rotary Vol. 2 No. 1. Analisa Efektivitas Heat Transfer SAH PLTU dengan Metode Asme 4.0 dan 4.3.
Mulyono, Anis Roihatin, Phypit Marisa. 2019. Jurnal Teknik Energi Vol. 15 No. 2. Analisis Pengaruh Pengganti Heating Element Terhadap Kinerja Air Preheater Type Ljungstorm di PLTU Jateng 2 Adipala 1 x 660 MW.
Vendy Antono, Ismail Darmawan. 2016. Jurnal Power Plant Vol. 4 No. 3 Jurnal. Analisis Efisiensi Air Preheater Sebelum Overhaul dan Sesudah Overhaul di UJP PLTU Banten 3 Lontar Unit 3.
Downloads
Published
Issue
Section
Citation Check
License
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution-ShareAlike 4.0 International License that allows others to share and adapt the work with an acknowledgement of the works authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journals published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
- Upon receiving the proofs, the Author/Editor agrees to promptly check the proofs carefully, correct any errors, and authorize the publication of the corrected proofs.